The information stored for each measurement consists of the test function and all user selectable test conditions. Data for each measurement is assigned a data set number, data subset number, and a data id number.

Memory location fields are used as described below. Use the data set field a to indicate a location such as a room or electrical panel number. Use the data subset field b for circuit number. The data id number field c is the measurement number. The measurement number automatically increments. The measurement number can also be set to a previously used value to overwrite an existing measurement. To enter Memory mode: 1. Press the M to enter Memory mode. The display changes to a memory mode display.

In Memory mode, the N icon appears on the display. The primary numeric display will be active with the left two digits a indicating the data set number and the right two digits b indicating the data subset number. The decimal point separating these two values will be active. The secondary numeric display c will be active indicating the data id number The memory locations a, b, or c will flash, indicating that you can change the number using the arrow keys U.

To enable the data subset number to be changed, press 1. The data subset number will now be flashing. To enable the data sub number to be changed, press 1 again. The data set number will now be flashing. Press 1 again to change the data id number. Storing and Recalling Measurements: 3. Press the down arrow key U to decrement the enabled number or press the up arrow key U to increment the enabled number.

For storing data, the number can be set to any value, overwriting existing data is allowed. For recalling data, the number can only be set to used values. Note: If you press the up or down arrow key U once, the number increments or decrements by one.

If you press and hold the up or down arrow, the numbers increment or decrement quickly by approximately 10 digits per second. To store a measurement: 1. Press M to enter Memory mode. Press 1 and use the arrow keys U to set the data identity. Press 2 to save the data. If memory is full, FULL will appear on the primary display. Press 1 to choose another data identity, press M to exit Memory mode.